SMA Sunny Tripower 3 kVA Inverter: Performance at the Service of Your Solar Energy
The SMA Sunny Tripower 3 kVA is a leading choice for solar energy conversion. With its 3000 VA power and 2 MPPT trackers, it optimizes the performance of your photovoltaic system, even under partial shading conditions. Designed for small residential and commercial installations, it offers a reliable and high-performance solution.
Why choose the SMA Sunny Tripower 3 kVA inverter?
Key Benefits:
SMA Sunny Tripower 3 kVA: Solar energy within reach.
DescriptionEconomical
Flexible
Interactive
Simple

| Technical data | Sunny Tripower 3.0 | Sunny Tripower 4.0 | Sunny Tripower 5.0 | Sunny Tripower 6.0 |
| Input (DC) | 6000 Wp |
| Wp | |
| Wp | |
| Wp |
| Max. power of photovoltaic generator | 850 V | |||
| Max. input voltage | 140 | ||
| V to 800 V | 175 V to 800 V | 215 V to 800 V | 260 V to 800 V |
| MPP voltage range | |||
| V | |||
| Rated input voltage | 125 V / 150 V | |||
| Input voltage min. | ||||
| / start-up input voltage Max. input current input A / input B | 12 A / 12 A | |||
| Max. short-circuit current. | ||||
| input A / input B | 18 A / 18 A | |||
| Number of independent MPP inputs / strings per MPP input Output (AC) | |||
| / A:1; B:1 | |||
| Rated power (at 230 V, 50 Hz) | 3000 W | 4000 W | 5000 W | 6000 W |
| Max. apparent AC power | 3000 | ||
| VA | 4000 VA | 5000 VA | 6000 VA |
| Rated AC voltage | |||
| ; 220 V / 380 V 3/N/PE; 230 V / 400 V 3/N/PE; | |||
| 240 V / 415 V | |||
| AC voltage range | 180 V to 280 V | |||
| AC mains frequency / Range | 50 Hz / 45 Hz to 55 Hz 60 Hz to 65 Hz | |||
| Rated mains frequency / Rated mains voltage | 50 Hz / 230 V | |||
| Max. output current | 3 |
| x 4.5 A | |
| x 5.8 A | |
| x 7.6 A | |
| x 9.1 A |
| Power factor at rated power / adjustable phase shift factor Injection phases / Connection phases | |||
| / 0.8 inductive to 0.8 capacitive | |||
| Efficiency |
| Max. efficiency. | / European efficiency | 98.2 % / 96.5 % | 98.2 % / 97.1 | 98.2 % / 97.4 % | 98.2 % / 97,6 % |
| Protective devices |
| Input-side disconnection device | ● | |||
| Ground fault monitoring / network monitoring | ●/● | |||
| DC reverse polarity protection / AC short-circuit resistance / galvanic separation | ●/●/- | |||
| Fault current monitoring unit, | ||||
| sensitive to all currents Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | ● | |||
| Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | |||
| / III | |||
| General features |
| Dimensions (L/H/P) | |||
| mm / 470 mm / 176 mm (17,1 inches / 18.5 inches / 6.9 inches) | |||
| Weight | 17 kg (37.4 lb) | |||
| Operating temperature range | -25 °C to +60 °C (-13 °F to +140 °F) | |||
| Noise emissions, typical | 30 dB(A) | |||
| Autoconsumption (night) | |||
| ,0 W | |||
| Topology / Cooling system | Transformerless / Convection | |||
| Protection class (to IEC 60529) | IP65 | |||
| Climatic class (to IEC 60721-3-4) |
| Maximum permissible value for relative air humidity (non-condensing) Equipment | 100,00% | |||
| Equipment |
| DC | ||||
| / AC connection | SUNCLIX / AC plug | |||
| Shade management : | ||||
| OptiTrac Global Peak / TS4-R | ●/○ | |||
| Warranty : | ||||
| 5 / 10 / 15 years | ●/○/○ | |||
| Certifications and approvals (others on request) | AS 4777, C10/11, CE, CEI 0-21, DIN EN 62109-1/IEC 62109-1, DIN EN 62109-2/IEC 62109-2, EN 50438, G59/3, G83/2, NEN-EN 50438, ÖVE / ÖNORM E 8001-4-712, PPDS, PPC, RD 1699, SI 4777, TR 3.2.1, UTE C15-712, VDE-AR-N 4105, VDE-0126-1-1, VFR 2014 | |||
| Certifications and approvals (planned) | DEWA 2016, EN 62116, IEC 61727, IE-EN 50438, NBR 16149, NRS 097-2-1 | |||
| Type designation | STP3.0-3AV-40 | STP4.0-3AV-40 | STP5.0-3AV-40 | STP6.0-3AV-40 |